Låse/Interface/skifte relæer

Links between logic and load

The DOLD toggle, coupling and switch relays are the first choice for all interface applications in demanding control systems. They connect the highly sensitive logic level of the SPS, a shelf system or process computer with the raw operation of the power levels of a machine. Installation and maintenance of the relays can be conducted in a time-saving manner with the snap-on plug-in sockets on the top-hat rail. Your additional benefit: They are not sensitive to overcurrent and/or overloads and are significantly less expensive that semiconductors with medium to low switching frequency.
Latching relay MK 8852
• According to IEC/EN 61 810-1
• Setting input A1 - A2
• Reset input A3 - A2
• Storage function
• Switch position indication
• Manual operation
• Width 22.5 mm
Download datablad
Latching relay AD 8851
• According to IEC/EN 61 810-1
• Manual operation possible
• Contact position indication via control lever
• max. 4 NC contacts, 4 NO contacts
• Width 45 mm
Download datablad
Latching relay UG 8851
• According to IEC/EN 61810-1
• With forcibly guided contacts according to DIN EN 50205
• With manual operation and contact position indication via control lever
• With impulse energization A1 - A2
• With reset pulse B1 - B2
• 4 NC contacts, 4 NO contacts or 4 changeover contacts
• With pluggable terminal blocks for easy exchange of devices
• Width 22.5 mm
Download datablad
Stepping relay BA 7632
• According to IEC/EN 61 810-1
• High switching capacity of contacts
• High switching safety
• Width 45 mm
Download datablad
Interface relay / input-output IG 3051
• According to IEC/EN 60 255, IEC/EN 61 810-1
• Input for AC/DC 24 V, AC 110 V or 230 V, as required
• 1 NO contact for AC 230 V
• LED indicator
• Width 9 mm
Download datablad
Interface relay / input-output ML 3045
Interface relay / input-output CA 3056
• According to IEC/EN 60 947-5-1
• Protective separation acc. to IEC/EN 61 140, IEC/EN 60 947-1:
6 kV/2, at CA/CB
• As option goldplated contacts (10 μm Au) to switch low loads
• LED indication
• Optionally with 1 NO contact, 1 NC contact, 1 C/O contact,
2 C/O contacts, 2 NO contacts
• Optionally with MOV on input to achieve higher surge immunity
• Width: 11.5 mm
Download datablad
Interface relay / input-output CB 3056
• According to IEC/EN 60 947-5-1
• Protective separation acc. to IEC/EN 61 140, IEC/EN 60 947-1:
6 kV/2, at CA/CB
• As option goldplated contacts (10 μm Au) to switch low loads
• LED indication
• Optionally with 1 NO contact, 1 NC contact, 1 C/O contact,
2 C/O contacts, 2 NO contacts
• Optionally with MOV on input to achieve higher surge immunity
• Width: 11.5 mm
Download datablad
Interface relay / input-output CC 3056
• According to IEC/EN 60 947-5-1
• Protective separation acc. to IEC/EN 61 140, IEC/EN 60 947-1:
6 kV/2, at CA/CB
• As option goldplated contacts (10 μm Au) to switch low loads
• LED indication
• Optionally with 1 NO contact, 1 NC contact, 1 C/O contact,
2 C/O contacts, 2 NO contacts
• Optionally with MOV on input to achieve higher surge immunity
• Width: 11.5 mm
Download datablad
Interface relay / input-output MK 8804N
• According to IEC/EN 61 810-1
• As option to switch low loads
• As option for 2-wire proximity sensor control
• Output: 4 changeover contacts
• With LED indicator
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
Download datablad
Interface relay / input-output IK 3076
• According to IEC/EN 60 255, IEC/EN 61 810-1
• Protective separation according to IEC/EN 61 140,
IEC/EN 60 947-1 in configuration with 1 changeover contact
• With input wiring protection against voltage surges
• With 1 or 2 changeover contacts as options
• High permanent current Ith
• For switching low loads as an option
• LED indicator
• Devices available in 2 enclosure version:
IK 3076: depth 59 mm with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
SK 3076: depth 98 mm with terminals at the top for
cabinets with mounting plate and cable duct
• Width 17.5 mm
Download datablad
Interface relay / input-output SK 3076
• According to IEC/EN 60 255, IEC/EN 61 810-1
• Protective separation according to IEC/EN 61 140,
IEC/EN 60 947-1 in configuration with 1 changeover contact
• With input wiring protection against voltage surges
• With 1 or 2 changeover contacts as options
• High permanent current Ith
• For switching low loads as an option
• LED indicator
• Devices available in 2 enclosure version:
IK 3076: depth 59 mm with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
SK 3076: depth 98 mm with terminals at the top for
cabinets with mounting plate and cable duct
• Width 17.5 mm
Download datablad
Interface relay / input-output IK 8802
• According to IEC/EN 60 255, IEC/EN 61 810-1
• With 1 or 2 changeover contacts as options
• High permanent current Ith
• For switching low loads as an option
• LED display (for AC/DC 24 V only)
• Width 17.5 mm
Download datablad
Interface relay / input-output IK 8701
• According to IEC/EN 61 810-1
• Optionally contacts with up to a maximum 4 changeover contacts
• High thermal current Ith
• Pushbutton for manual actuation of the contact
• Operating position display
• Optionally without manual actuation and an operating position display
• Optionally for 2-wire initiator activation
• Optionally for switching low loads
• Optionally for switching lamps with parallel compensation (e.g. HQ lamps)
• Optionally for switching large inductive direct current loads
• Optionally with a recovery diode (only DC devices)
• Optionally with reliable release voltage of AC 120 V
• IK 8701: width 17.5 mm
IL 8701: width 35 mm
IN 8701: width 52.5 mm
Download datablad
Interface relay / input-output IL 8701
• According to IEC/EN 61 810-1
• Optionally contacts with up to a maximum 4 changeover contacts
• High thermal current Ith
• Pushbutton for manual actuation of the contact
• Operating position display
• Optionally without manual actuation and an operating position display
• Optionally for 2-wire initiator activation
• Optionally for switching low loads
• Optionally for switching lamps with parallel compensation (e.g. HQ lamps)
• Optionally for switching large inductive direct current loads
• Optionally with a recovery diode (only DC devices)
• Optionally with reliable release voltage of AC 120 V
• IK 8701: width 17.5 mm
IL 8701: width 35 mm
IN 8701: width 52.5 mm
Download datablad
Interface relay / input-output IN 8701
• According to IEC/EN 61 810-1
• Optionally contacts with up to a maximum 4 changeover contacts
• High thermal current Ith
• Pushbutton for manual actuation of the contact
• Operating position display
• Optionally without manual actuation and an operating position display
• Optionally for 2-wire initiator activation
• Optionally for switching low loads
• Optionally for switching lamps with parallel compensation (e.g. HQ lamps)
• Optionally for switching large inductive direct current loads
• Optionally with a recovery diode (only DC devices)
• Optionally with reliable release voltage of AC 120 V
• IK 8701: width 17.5 mm
IL 8701: width 35 mm
IN 8701: width 52.5 mm
Download datablad
Input-Output interface relay IK 3070
• According to IEC/EN 61 810-1
• Relay, triac or transistor output
• Protective separation according to IEC/EN 61 140,
IEC/EN 60 947-1 on devices with relay output (only at
IK 3070.01 / _0_,
IK 3070.02 /_0_,
IK 3070.11 /_0_)
• LED as operating position display
• Optionally input wiring with recovery diode or MOV
• Optionally for small switching currents
• Optionally with forcibly guided contacts
• As option with 3-position test switch:
Auto, Off, Manual/Sensor control (+ 24 V)
• As option with semiconductor output
- for high switching frequency
- input protection with varistor
• Optionally interface relay system to reduce the amount of wiring
• IK 3070: width 17.5 mm
IS 3070: width 140 mm
Download datablad
Input-Output interface relay IS 3070
• According to IEC/EN 61 810-1
• Relay, triac or transistor output
• Protective separation according to IEC/EN 61 140,
IEC/EN 60 947-1 on devices with relay output (only at
IK 3070.01 / _0_,
IK 3070.02 /_0_,
IK 3070.11 /_0_)
• LED as operating position display
• Optionally input wiring with recovery diode or MOV
• Optionally for small switching currents
• Optionally with forcibly guided contacts
• As option with 3-position test switch:
Auto, Off, Manual/Sensor control (+ 24 V)
• As option with semiconductor output
- for high switching frequency
- input protection with varistor
• Optionally interface relay system to reduce the amount of wiring
• IK 3070: width 17.5 mm
IS 3070: width 140 mm
Download datablad
Interface relay ML 3059
• According to IEC/EN 60 255, IEC/EN 61 810-1
• Optionally safe separation according to IEC/EN 61 140,
IEC/EN 60 947-1, 6 kV/2
- between coil and contacts
- between the two contacts
• As option with reduced power consumption
• Optionally for switching of low loads
• 1 or 2 changeover contacts
• for AC/DC 12 ... 240 V
• For 2-wire proximity sensors
• LED indicator
• Width 22.5 mm
Download datablad
Output switching relay system CB 3057
• According to IEC/EN 60 255, IEC/EN 61 810-1
• With service switch Auto/On/Off
• Test possible without influence on PLC
• Input AC/DC 24 V
• 1 changeover contact 5 A
• LED indicator
• Width 11.5 mm
Download datablad
Interface relay UG 3076/007
• UG 3076.12: 2 changeover contact
UG 3076.15: 6 changeover contact
• Safe release voltage: the output relay is de-energized at U < 27 % UN • Width 22.5 mm
Download datablad
Interface module with plug-type socket HC 3093
• According to DIN EN 61810
• 2 output contacts with monostable PCB-relay OA 5668
• Version with bistable PCB-relay OB 5694
• Contact material AgNi with fine gold
• High thermal current up to Ith = 16 A with relays
OA 5682 and OB 5694
• Large temperature range: - 40 ... + 85 °C
• As option with free-wheel diode or varistor between A1/A2
• As option with AgSnO2 or AgNi with hard gold
• Width: 15.8 mm
Download datablad
Interface module, with plug-type socket HC 3096N
• According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60 947-5-1
• With forcibly guided contacts according to IEC 61810-3
• Models with soldered in or plug-in PCB safety relay consisting of:
- plug in socket HC 3096N and safety relay OA 5611
- plug in socket HL 3096N and safety relay OA 5612
• With polarity protected diode
• Optionally with free-wheeling diode across A1+ and A2
• Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au
• For DIN rail mounting according IEC/EN 60715
• HC 3096N: width 18 mm
HL 3096N: width 36 mm
Download datablad
Interface module, with plug-type socket HL 3096N
• According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60 947-5-1
• With forcibly guided contacts according to IEC 61810-3
• Models with soldered in or plug-in PCB safety relay consisting of:
- plug in socket HC 3096N and safety relay OA 5611
- plug in socket HL 3096N and safety relay OA 5612
• With polarity protected diode
• Optionally with free-wheeling diode across A1+ and A2
• Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au
• For DIN rail mounting according IEC/EN 60715
• HC 3096N: width 18 mm
HL 3096N: width 36 mm
Download datablad