DOLD interference suppressors of the INFOMASTER family use lamps, signals or text notifications to inform about interferences and the conditions of electrical systems in industrial settings and buildings. In addition, they are also used to define maintenance intervals for preventive maintenance. Especially in the event of interferences in complex machine and systems, they can decisively reduce the length of the search for interferences. This minimises standstill times of the production system and helps to save on costs. The compact DOLD interference suppressor ensures a cost-efficient monitoring of small machines without SPS, such as compressors. Thanks to it modular construction, it can grow with the system through expansions.
![]() | Fault annunciator system EH 9997 • Common alarm annunciator for 6 signals • Optionally for up to 8 signals • Closed circuit operation • Optionally with open circuit operation • With LED for each fault signal • Inputs up to AC/DC 300 V • With relay output for common signal • Pushbutton for fault signal acknowledgement and function test • Front surface 96 x 96 mm | Download datablad |
![]() | Fault annunciator AD 5960 • According to IEC/EN 60 255, DIN VDE 0435-303 • Common alarm annunciator for 12 signals • 1 relay for common signal and horn • Inputs up to AC/DC 230 V • 1 connection for acknowledgement button of horn and lamp test • Width: 45 mm | Download datablad |
![]() | Fault annunciator IL 5990 • According to DIN 19235 • Common alarm annunciator • Expandable from 4 up to 160 inputs • Open circuit inputs / closed circuit inputs selectable via bridges X1-X2 • Delayed inputs up to 10 s • Acknowledgement push button QH for external buzzer built in • Accessories: Buzzer IK 8832, SK 8832 • Devices available in 2 enclosure versions: I-model: depth 61 mm, with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880 S-model: depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct • Width 35 mm Fault annunciator IL 5990, SL 5990: • 4 inputs with LED on control unit • 1 output for common signal and 1 output for audible alarm | Download datablad |
![]() | Fault annunciator IL 5991 • According to DIN 19235 • Common alarm annunciator • Expandable from 4 up to 160 inputs • Open circuit inputs / closed circuit inputs selectable via bridges X1-X2 • Delayed inputs up to 10 s • Acknowledgement push button QH for external buzzer built in • Accessories: Buzzer IK 8832, SK 8832 • Devices available in 2 enclosure versions: I-model: depth 61 mm, with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880 S-model: depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct • Width 35 mm Extension unit IL 5991, SL 5991: • 4 inputs with LED on control unit | Download datablad |
![]() | Fault annunciator system SL 5990 • According to DIN 19235 • Common alarm annunciator • Expandable from 4 up to 160 inputs • Open circuit inputs / closed circuit inputs selectable via bridges X1-X2 • Delayed inputs up to 10 s • Acknowledgement push button QH for external buzzer built in • Accessories: Buzzer IK 8832, SK 8832 • Devices available in 2 enclosure versions: I-model: depth 61 mm, with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880 S-model: depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct • Width 35 mm Fault annunciator IL 5990, SL 5990: • 4 inputs with LED on control unit • 1 output for common signal and 1 output for audible alarm | Download datablad |
![]() | Fault annunciator SL 5991 • According to DIN 19235 • Common alarm annunciator • Expandable from 4 up to 160 inputs • Open circuit inputs / closed circuit inputs selectable via bridges X1-X2 • Delayed inputs up to 10 s • Acknowledgement push button QH for external buzzer built in • Accessories: Buzzer IK 8832, SK 8832 • Devices available in 2 enclosure versions: I-model: depth 61 mm, with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880 S-model: depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct • Width 35 mm Extension unit IL 5991, SL 5991: • 4 inputs with LED on control unit | Download datablad |
![]() | Fault annunciator RP 5990 Common Alarm Annunciator RP 5990, RP 5991 • Fast localisation of failures and their causes • Reduction of standstill times in production • Common alarm annunciator with manual or auto reset of faults • Expandable from 8 to 88 fault signals • Open or closed circuit operation settable with rotational switch on base unit and with link X1/X2 on extension units • Adjustable on delay for input signals 0 to 10 sec • Reset buttons for audible alarm and common alarm on front side • Connection for external reset of audible alarm • Galvanic separation to bus RS485 (optional) • Accessories: buzzer RK 8832, display unit EH 5990, EH 5991 • Width: 70 mm • Base Module RP 5990: - 8 fault signal inputs with indicator LED on the unit - One relay output each for audible alarm and common alarm - Reset buttons for audible alarm and common alarm - Connection for external reset of audible alarm • Extension Module RP 5991: - 8 fault signal inputs with indicator LED on the unit - As option one relay output each for audible alarm and common alarm - As option reset buttons for audible alarm and common alarm | Download datablad |
![]() | Fault annunciator RP 5991 Common Alarm Annunciator RP 5990, RP 5991 • Fast localisation of failures and their causes • Reduction of standstill times in production • Common alarm annunciator with manual or auto reset of faults • Expandable from 8 to 88 fault signals • Open or closed circuit operation settable with rotational switch on base unit and with link X1/X2 on extension units • Adjustable on delay for input signals 0 to 10 sec • Reset buttons for audible alarm and common alarm on front side • Connection for external reset of audible alarm • Galvanic separation to bus RS485 (optional) • Accessories: buzzer RK 8832, display unit EH 5990, EH 5991 • Width: 70 mm • Base Module RP 5990: - 8 fault signal inputs with indicator LED on the unit - One relay output each for audible alarm and common alarm - Reset buttons for audible alarm and common alarm - Connection for external reset of audible alarm • Extension Module RP 5991: - 8 fault signal inputs with indicator LED on the unit - As option one relay output each for audible alarm and common alarm - As option reset buttons for audible alarm and common alarm | Download datablad |
![]() | New-value and first-up annunciator system RP 5994 New- / First- /Common Signal Annunciator RP 5994, RP 5995 • Fast localisation of failures and their causes • Reduction of standstill times in production • Adjustable operating modes: New- / First signal annunciator according to DIN 19 235, common alarm annunciator manual reset / auto reset settable • Expandable from 8 to 88 fault signals • Open or closed circuit operation settable • Adjustable on delay for input signals 0 to 10 sec • Reset buttons for audible alarm and common alarm on front side • Connection for external reset of audible alarm, common alarm and single alarm according to setting • Galvanic separation to bus RS485 (optional) • Accessories: buzzer RK 8832, display unit EH 5994, EH 5995 text display unit EH 5996, GMS-module RP 5810 • Width: 70 mm Base module RP 5994: - 8 fault signal inputs with indicator LED on the unit - One relay output each for audible alarm and common alarm - Reset buttons for audible alarm, common alarm, and single alarm - Connection of remote reset button. Function according to setting Extension module RP 5995: - 8 fault signal inputs with indicator LED on the unit - One relay output each for audible alarm and common alarm (on request) - Reset buttons for audible alarm, common alarm, and single alarm - Connection of remote reset button. Function according to setting | Download datablad |
![]() | New-value and first-up annunciator system RP 5995 New- / First- /Common Signal Annunciator RP 5994, RP 5995 • Fast localisation of failures and their causes • Reduction of standstill times in production • Adjustable operating modes: New- / First signal annunciator according to DIN 19 235, common alarm annunciator manual reset / auto reset settable • Expandable from 8 to 88 fault signals • Open or closed circuit operation settable • Adjustable on delay for input signals 0 to 10 sec • Reset buttons for audible alarm and common alarm on front side • Connection for external reset of audible alarm, common alarm and single alarm according to setting • Galvanic separation to bus RS485 (optional) • Accessories: buzzer RK 8832, display unit EH 5994, EH 5995 text display unit EH 5996, GMS-module RP 5810 • Width: 70 mm Base module RP 5994: - 8 fault signal inputs with indicator LED on the unit - One relay output each for audible alarm and common alarm - Reset buttons for audible alarm, common alarm, and single alarm - Connection of remote reset button. Function according to setting Extension module RP 5995: - 8 fault signal inputs with indicator LED on the unit - One relay output each for audible alarm and common alarm (on request) - Reset buttons for audible alarm, common alarm, and single alarm - Connection of remote reset button. Function according to setting | Download datablad |
![]() | Indications panel for fault annunciator system EH 5990 Display Unit EH 5990, EH 5991 • Exchangable front label for individual legending • As option galvanic separated RS458 bus • Protection degree for front side IP64 • Enclosure for flush mounting 96 x 96 mm • Display Unit EH 5990: - 8 fault signal LEDs on the unit - Reset buttons for audible alarm and common alarm • Display Unit EH 5991: - 8 fault signal LEDs on the unit - Without reset buttons | Download datablad |
![]() | Indications panel for fault annunciator system EH 5991 Display Unit EH 5990, EH 5991 • Exchangable front label for individual legending • As option galvanic separated RS458 bus • Protection degree for front side IP64 • Enclosure for flush mounting 96 x 96 mm • Display Unit EH 5990: - 8 fault signal LEDs on the unit - Reset buttons for audible alarm and common alarm • Display Unit EH 5991: - 8 fault signal LEDs on the unit - Without reset buttons | Download datablad |
![]() | Indications panel for new-value and first-up annunciator system EH 5994 Display unit EH 5994, EH 5995 • Exchangable front label for individual legending • As option galvanic separated RS458 bus • Protection degree for front side IP 64 • Enclosure for flush mounting 96 x 96 mm • Display unit EH 5994: - 8 fault signal LEDs on the unit - Reset buttons for audible alarm, common alarm and alarm signal • Display unit EH 5995: - 8 fault signal LEDs on the unit - Without reset buttons | Download datablad |
![]() | Indications panel for new-value and first-up annunciator system EH 5995 Display unit EH 5994, EH 5995 • Exchangable front label for individual legending • As option galvanic separated RS458 bus • Protection degree for front side IP 64 • Enclosure for flush mounting 96 x 96 mm • Display unit EH 5994: - 8 fault signal LEDs on the unit - Reset buttons for audible alarm, common alarm and alarm signal • Display unit EH 5995: - 8 fault signal LEDs on the unit - Without reset buttons | Download datablad |
![]() | Textdisplay unit, fault annunciator system with bus connection EH 5996 • Text display for DOLD fault annunciator system INFOMASTER B with base module RP 5994 • To display up to 88 fault messages with 80, 40 or 20 characters each • Operating mode adjustable on base module RP 5994 for new, first or common alarm • Reset buttons for individual alarm signal, audible alarm and common alarm on front side • RS 485 bus connection, as option with galvanic separation • Alarms and resets can be transmitted by SMS via GSM module RP 5810 • SMS communication is possible with up to 16 receivers • Configuration of the text display via USB-Stick (acceccories OA 5996 Article-No. 0065659), therefore no laptop on site is necessary • Real time clock • Operating language for menus and failure text in English, German and French • Up to 3 variable parameters in one message text • 2 password levels for device configuration | Download datablad |
![]() | New-value annunciator EP 5966 • New fault annunciation with single frequency flashlight according to DIN 19 235 • Expandable from 16 up to 160 inputs • in 2 groups of 8 inputs selectable: - open circuit operation - closed circuit operation • Input voltage up to max. AC/DC 240 V • Delayed inputs • Exchangable front for individual scale • Removable terminals • Flush mounting • Frame 72 x 144 mm EP 5966: • 16 inputs in control unit • Output relay for common signal and audible alarm • Built in and external connected pushbuttons for lamp test (LT), acknowledgement of horn (QH) and of alarm (QS) • Extension module with 16 inputs | Download datablad |
![]() | New-value annunciator EP 5967 • New fault annunciation with single frequency flashlight according to DIN 19 235 • Expandable from 16 up to 160 inputs • in 2 groups of 8 inputs selectable: - open circuit operation - closed circuit operation • Input voltage up to max. AC/DC 240 V • Delayed inputs • Exchangable front for individual scale • Removable terminals • Flush mounting • Frame 72 x 144 mm | Download datablad |
![]() | New-value annunciator AD 5998 • New fault annunciation according to DIN 19235 • Expandable from 3 up to 303 inputs • Width 45 mm Fault annunciator AD 5998: • 3 inputs • Pushbutton connection possible for light signal acknowledgement, horn acknowledgement and lamp test • 1 relay for common alarm and 1 for horn Extension unit AD 5992: • 6 inputs | Download datablad |
![]() | New-value annunciator AD 5992 • New fault annunciation according to DIN 19235 • Expandable from 3 up to 303 inputs • Width 45 mm Fault annunciator AD 5998: • 3 inputs • Pushbutton connection possible for light signal acknowledgement, horn acknowledgement and lamp test • 1 relay for common alarm and 1 for horn Extension unit AD 5992: • 6 inputs | Download datablad |
![]() | GSM Modul bus-compatible RP 5810 | |
![]() | SMS Telecontrol module RP 5812 • According to directive 1999/5/EC (RTTE) for radio equipment and telecommunications terminal equipment • 4 digital inputs and 4 relay outputs • Variant RP 5812/001 with 2 digital and 2 analogue inputs and 1 analogue - and 2 relay outputs • Auxiliary voltage DC 24 V • DC 24 V digital inputs • Automatic SMS messages for status changes • Quad-Band GSM-Module for 850, 900, 1800 and 1900 MHz (GSM = Global System for Mobile) • Pin protection of SIM card • Caller password protection against unauthorised access • User Dialogue language for: German, English or French • Configurable authorization levels for up to 16 users • Assignment of different I/O’s to different users • Automatic sending of SMS when digital inputs change state I.e. come on or go off or both (on rising edge or falling edge) • Automatic sending of SMS when analogue inputs - exceed preset lower and upper limits or - when signal is within the preset window - and when the signal returns to good state • Adjustable - Hysteresis for analogue inputs - Time delay for each input - Repeat time for SMS-transmitting - Time delay for output status after starting the unit - Time delay for activation of the output • SMS for device status to the system administrators • SMS-counter to monitor the remaining account • No interruption of operation after Voltage failure due to integrated Li-Ion battery backup 24Hours • Compact width: 70 mm | Download datablad |
![]() | Lamp tester MK 9994 • For max. 11 indicator lamps • Width 22.5 mm | Download datablad |
![]() | Alarm buzzer IK 8832 • Permanent sound, pitch fixed • optionally with switchable interval- / permanent sound • Devices available in 2 enclosure versions: - I- and-version, e.g. IK _ _ _ _ with depth 61 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880, - S-version, e.g. SK _ _ _ _ with depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct • Width: 17,5 mm | Download datablad |
![]() | Buzzer SK 8832 • Permanent sound, pitch fixed • optionally with switchable interval- / permanent sound • Devices available in 2 enclosure versions: - I- and-version, e.g. IK _ _ _ _ with depth 61 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880 - S-version, e.g. SK _ _ _ _ with depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct • Width: 17,5 mm | Download datablad |
![]() | Buzzer RK 8832 • Permanent sound, pitch fixed • optionally with switchable interval- / permanent sound and 2 pitches settable • Width: 17.5 mm and depth: 64 mm | Download datablad |