Målerelæer til strøm overvågning

Current Relay MK 9053N
• According to IEC/EN 60 255-1, IEC/EN 60 947-1
• to: monitor DC and AC
• BA 9053 with measuring ranges from 2 mA to 25 A
• BA 9053 optionally with 3 measuring ranges 0.1 up to 25 A
• MK 9053N with measuring ranges from 2 mA up to 10 A
• High overload possible
• Input frequency up to 5 kHz
• Galvanic separation between auxiliary circuit - measuring ciruit
• Auxiliary supply AC/DC; BA 9053 with AC
• BA 9053 optionally with start-up delay (MK = standard)
• with time delay, up to max. 100 sec
• BA 9053 optionally with safe separation to IEC/EN 61140
• MK 9053N optionally with remote potentiometer
• As option with manual reset
• LED indicators for operation and contact position
• MK 9053N as option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width BA 9053: 45 mm
Width MK 9053N: 22.5 mm
Download datablad
Current Relay BA 9053
• According to IEC/EN 60 255-1, IEC/EN 60 947-1
• to: monitor DC and AC
• BA 9053 with measuring ranges from 2 mA to 25 A
• BA 9053 optionally with 3 measuring ranges 0.1 up to 25 A
• MK 9053N with measuring ranges from 2 mA up to 10 A
• High overload possible
• Input frequency up to 5 kHz
• Galvanic separation between auxiliary circuit - measuring ciruit
• Auxiliary supply AC/DC; BA 9053 with AC
• BA 9053 optionally with start-up delay (MK = standard)
• with time delay, up to max. 100 sec
• BA 9053 optionally with safe separation to IEC/EN 61140
• MK 9053N optionally with remote potentiometer
• As option with manual reset
• LED indicators for operation and contact position
• MK 9053N as option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width BA 9053: 45 mm
Width MK 9053N: 22.5 mm
Download datablad
Current relay MK 9063N
• According to IEC/EN 60 255-1
• AC/DC current measuring (single-phase)
• Start up delay, on delay
• Manual reset
• LCD for indication of the measuring values
• Relay output
MK 9063N: 1 changeover contact
MH 9063: 2 x 1 changeover contacts
• Relay function selectable (energized/de-energized on trip)
• As option with plugable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width MK 9063N: 22.5 mm
• Width MH 9063: 45.0 mm
Download datablad
Current relay MH 9063
• According to IEC/EN 60 255-1
• AC/DC current measuring (single-phase)
• Start up delay, on delay
• Manual reset
• LCD for indication of the measuring values
• Relay output
MK 9063N: 1 changeover contact
MH 9063: 2 x 1 changeover contacts
• Relay function selectable (energized/de-energized on trip)
• As option with plugable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width MK 9063N: 22.5 mm
• Width MH 9063: 45.0 mm
Download datablad
Over- and Undercurrent Relay IL 9277
• According to IEC/EN 60 25-1
• IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase
• Detects over- and undercurrent
• Measuring ranges from 0.1 ... 15 A
• With built in current transformer for 0.5 ... 100 A
• IL 9277, SL 9277 with 4 programmable ranges
• Settable 0.1 ... 1 IN
• Separate setting for over- and undercurrent
• Fixed hysteresis approx. 4 %
• Settable time delay
• IP 9277, SP 9277 with separate settable time delay for
over- and undercurrent
• De-energized on trip
• LED indicators for over-, under- and normal current
• Auxiliary supply and measuring input galvanic separated
• IL 9277, SL 9277 with one output relay for over- and
undercurrent
• IP 9277, SP 9277 with separate output relays for over- and
undercurrent
• Optionally energized on trip
• Devices available in 2 enclosure versions:
-- I-model, e.g. IL _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
-- S-model, e.g. SL _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• DIN rail or screw mounting
• Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Download datablad
Over- and Undercurrent Relay SL 9277
• According to IEC/EN 60 25-1
• IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase
• Detects over- and undercurrent
• Measuring ranges from 0.1 ... 15 A
• With built in current transformer for 0.5 ... 100 A
• IL 9277, SL 9277 with 4 programmable ranges
• Settable 0.1 ... 1 IN
• Separate setting for over- and undercurrent
• Fixed hysteresis approx. 4 %
• Settable time delay
• IP 9277, SP 9277 with separate settable time delay for
over- and undercurrent
• De-energized on trip
• LED indicators for over-, under- and normal current
• Auxiliary supply and measuring input galvanic separated
• IL 9277, SL 9277 with one output relay for over- and
undercurrent
• IP 9277, SP 9277 with separate output relays for over- and
undercurrent
• Optionally energized on trip
• Devices available in 2 enclosure versions:
-- I-model, e.g. IL _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
-- S-model, e.g. SL _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• DIN rail or screw mounting
• Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Download datablad
Over- and Undercurrent Relay SL 9277CT
• According to IEC/EN 60 25-1
• IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase
• Detects over- and undercurrent
• Measuring ranges from 0.1 ... 15 A
• With built in current transformer for 0.5 ... 100 A
• IL 9277, SL 9277 with 4 programmable ranges
• Settable 0.1 ... 1 IN
• Separate setting for over- and undercurrent
• Fixed hysteresis approx. 4 %
• Settable time delay
• IP 9277, SP 9277 with separate settable time delay for
over- and undercurrent
• De-energized on trip
• LED indicators for over-, under- and normal current
• Auxiliary supply and measuring input galvanic separated
• IL 9277, SL 9277 with one output relay for over- and
undercurrent
• IP 9277, SP 9277 with separate output relays for over- and
undercurrent
• Optionally energized on trip
• Devices available in 2 enclosure versions:
-- I-model, e.g. IL _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
-- S-model, e.g. SL _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• DIN rail or screw mounting
• Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Download datablad
Over- and Undercurrent Relay IP 9277
• According to IEC/EN 60 25-1
• IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase
• Detects over- and undercurrent
• Measuring ranges from 0.1 ... 15 A
• With built in current transformer for 0.5 ... 100 A
• IL 9277, SL 9277 with 4 programmable ranges
• Settable 0.1 ... 1 IN
• Separate setting for over- and undercurrent
• Fixed hysteresis approx. 4 %
• Settable time delay
• IP 9277, SP 9277 with separate settable time delay for
over- and undercurrent
• De-energized on trip
• LED indicators for over-, under- and normal current
• Auxiliary supply and measuring input galvanic separated
• IL 9277, SL 9277 with one output relay for over- and
undercurrent
• IP 9277, SP 9277 with separate output relays for over- and
undercurrent
• Optionally energized on trip
• Devices available in 2 enclosure versions:
-- I-model, e.g. IL _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
-- S-model, e.g. SL _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• DIN rail or screw mounting
• Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Download datablad
Over- and Undercurrent Relay SP 9277
• According to IEC/EN 60 25-1
• IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase
• Detects over- and undercurrent
• Measuring ranges from 0.1 ... 15 A
• With built in current transformer for 0.5 ... 100 A
• IL 9277, SL 9277 with 4 programmable ranges
• Settable 0.1 ... 1 IN
• Separate setting for over- and undercurrent
• Fixed hysteresis approx. 4 %
• Settable time delay
• IP 9277, SP 9277 with separate settable time delay for
over- and undercurrent
• De-energized on trip
• LED indicators for over-, under- and normal current
• Auxiliary supply and measuring input galvanic separated
• IL 9277, SL 9277 with one output relay for over- and
undercurrent
• IP 9277, SP 9277 with separate output relays for over- and
undercurrent
• Optionally energized on trip
• Devices available in 2 enclosure versions:
-- I-model, e.g. IL _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
-- S-model, e.g. SL _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• DIN rail or screw mounting
• Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Download datablad
Over- and Undercurrent Relay SP 9277CT
• According to IEC/EN 60 25-1
• IP 9277, SP 9277, SP 9277CT: 3-phase
IL 9277, SL 9277, SL 9277CT: singele phase
• Detects over- and undercurrent
• Measuring ranges from 0.1 ... 15 A
• With built in current transformer for 0.5 ... 100 A
• IL 9277, SL 9277 with 4 programmable ranges
• Settable 0.1 ... 1 IN
• Separate setting for over- and undercurrent
• Fixed hysteresis approx. 4 %
• Settable time delay
• IP 9277, SP 9277 with separate settable time delay for
over- and undercurrent
• De-energized on trip
• LED indicators for over-, under- and normal current
• Auxiliary supply and measuring input galvanic separated
• IL 9277, SL 9277 with one output relay for over- and
undercurrent
• IP 9277, SP 9277 with separate output relays for over- and
undercurrent
• Optionally energized on trip
• Devices available in 2 enclosure versions:
-- I-model, e.g. IL _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
-- S-model, e.g. SL _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• DIN rail or screw mounting
• Width IL 9277, SL 9277, SL 9277CT: 35 mm
IP 9277, SP 9277, SP 9277CT: 70 mm
Download datablad
Current Asymmetry Relay SP 9278
• According to IEC/EN 60 255, DIN VDE 0435-303
• IP 9278, SP 9278: 3-phase
• Measuring range IP 9278, SP 9278: up to 15 A
SP 9278CT: up to 100 A
• 2 changeover contacts
• Adjustable asymmetry
• Settable time delay
• Open circuit operation
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• As option with external remote reset
• Width 70 mm
Download datablad
Current Asymmetry Relay SP 9278CT
• According to IEC/EN 60 255, DIN VDE 0435-303
• IP 9278, SP 9278: 3-phase
• Measuring range IP 9278, SP 9278: up to 15 A
SP 9278CT: up to 100 A
• 2 changeover contacts
• Adjustable asymmetry
• Settable time delay
• Open circuit operation
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• As option with external remote reset
• Width 70 mm
Download datablad
Overcurrent Relay IK 9270
• According to IEC/EN 60 255-1
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• As option energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
-- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
-- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Download datablad
Overcurrent Relay SK 9270
• According to IEC/EN 60 255-1
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• As option energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
-- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
-- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Download datablad
Overcurrent Relay IL 9270
• According to IEC/EN 60 255-1
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• As option energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
-- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
-- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Download datablad
Overcurrent Relay SL 9270
• According to IEC/EN 60 255-1
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• As option energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
-- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
-- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Download datablad
Overcurrent Relay SL 9270CT
• According to IEC/EN 60 255-1
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• As option energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
-- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
-- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Download datablad
Overcurrent Relay IP 9270
• According to IEC/EN 60 255-1
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• As option energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Download datablad
Overcurrent Relay SP 9270
• According to IEC/EN 60 255-1
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• de-energized on trip
• energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
Download datablad
Overcurrent Relay SP 9270CT
• According to IEC/EN 60 255-1
• IP 9270, SP 9270CT: 3-phase
IK 9270, SK 9270, IL 9270, SL 9270CT: single phase
• Measuring ranges from 0.1 ... 100 A
• Settable response value
• Fixed hysteresis
• Settable time delay
• de-energized on trip
• energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9270, SK 9270: 17.5 mm
IL 9270, SL 9270CT: 35 mm
IP 9270, SP 9270CT: 70 mm
Download datablad
Overcurrent Relay IK 9272
• According to IEC/EN 60 255
• Single phase
• Measuring ranges from 0.05 ... 10 A
• Fixed hysteresis approx. 4 %
• Adjustable switching delay
• Closed circuit operation
• Optionally open circuit operation
• Automatic reset
• Optionally manual reset, reset button on the front
• LED indication for auxiliary voltage
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9272: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9272: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
Download datablad
Overcurrent Relay SK 9272
• According to IEC/EN 60 255
• Single phase
• Measuring ranges from 0.05 ... 10 A
• Fixed hysteresis approx. 4 %
• Adjustable switching delay
• Closed circuit operation
• Optionally open circuit operation
• Automatic reset
• Optionally manual reset, reset button on the front
• LED indication for auxiliary voltage
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9272: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9272: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
Download datablad
Overcurrent Relay IL 5201/20007
• According to IEC/EN 60 255, DIN VDE 0435-303
• 2 independent relays in once enclosure
• 2 measuring ranges from 0.5 to 5 A
• Adjustable response values
• Fixed hysteresis
• Adjustable switching delay
• Closed circuit operation
• LED indicators
• with auyiliary voltage
• galvanic separation between Auxiliary Circuit and Measuring Circuit
• 2 models available:
IL 5201: 63 mm deep with terminals near to the bottom to be
mounted in consumer units or industrial distribution
systems according to DIN 43 880
SL 5201: 100 mm deep with terminals near to the top to be mounted
in cabinets with mounting plate and cable ducts
• Width: 35 mm
Download datablad
Overcurrent Relay SL 5201/20007CT
• According to IEC/EN 60 255, DIN VDE 0435-303
• 2 independent relays in once enclosure
• 2 measuring ranges from 0.5 to 5 A
• Adjustable response values
• Fixed hysteresis
• Adjustable switching delay
• Closed circuit operation
• LED indicators
• with auyiliary voltage
• galvanic separation between Auxiliary Circuit and Measuring Circuit
• 2 models available:
IL 5201: 63 mm deep with terminals near to the bottom to be
mounted in consumer units or industrial distribution
systems according to DIN 43 880
SL 5201: 100 mm deep with terminals near to the top to be mounted
in cabinets with mounting plate and cable ducts
• Width: 35 mm
Download datablad
Undercurrent Relay IK 9271
• According to IEC/EN 60 255-1
• IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: single phase
• Measuring ranges from 0.1 ... 100 A
• IK 9271, SK 9271:
with 4 ranges settable by rotational switch, 1 changeover contact
• IL 9271, SL 9271:
with 5 ranges settable by rotational switch, 1 changeover contact
with 4 ranges programmable by bridges, 2 changeover contacts
• IP 9271, SP 9271: with 1 range, 2 changeover contacts
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• Optionally energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Download datablad
Undercurrent Relay SK 9271
• According to IEC/EN 60 255-1
• IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: single phase
• Measuring ranges from 0.1 ... 100 A
• IK 9271, SK 9271:
with 4 ranges settable by rotational switch, 1 changeover contact
• IL 9271, SL 9271:
with 5 ranges settable by rotational switch, 1 changeover contact
with 4 ranges programmable by bridges, 2 changeover contacts
• IP 9271, SP 9271: with 1 range, 2 changeover contacts
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• Optionally energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Download datablad
Undercurrent Relay IL 9271
• According to IEC/EN 60 255-1
• IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: single phase
• Measuring ranges from 0.1 ... 100 A
• IK 9271, SK 9271:
with 4 ranges settable by rotational switch, 1 changeover contact
• IL 9271, SL 9271:
with 5 ranges settable by rotational switch, 1 changeover contact
with 4 ranges programmable by bridges, 2 changeover contacts
• IP 9271, SP 9271: with 1 range, 2 changeover contacts
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• Optionally energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Download datablad
Undercurrent Relay SL 9271
• According to IEC/EN 60 255, DIN VDE 0435-303
• IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: single phase
• Measuring ranges from 0.1 ... 100 A
• IK 9271, SK 9271:
with 4 ranges settable by rotational switch, 1 changeover contact
• IL 9271, SL 9271:
with 5 ranges settable by rotational switch, 1 changeover contact
with 4 ranges programmable by bridges, 2 changeover contacts
• IP 9271, SP 9271: with 1 range, 2 changeover contacts
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• Optionally energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Download datablad
Undercurrent Relay IP 9271
• According to IEC/EN 60 255, DIN VDE 0435-303
• IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: single phase
• Measuring ranges from 0.1 ... 100 A
• IK 9271, SK 9271:
with 4 ranges settable by rotational switch, 1 changeover contact
• IL 9271, SL 9271:
with 5 ranges settable by rotational switch, 1 changeover contact
with 4 ranges programmable by bridges, 2 changeover contacts
• IP 9271, SP 9271: with 1 range, 2 changeover contacts
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• Optionally energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Download datablad
Undercurrent Relay SP 9271
• According to IEC/EN 60 255, DIN VDE 0435-303
• IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: single phase
• Measuring ranges from 0.1 ... 100 A
• IK 9271, SK 9271:
with 4 ranges settable by rotational switch, 1 changeover contact
• IL 9271, SL 9271:
with 5 ranges settable by rotational switch, 1 changeover contact
with 4 ranges programmable by bridges, 2 changeover contacts
• IP 9271, SP 9271: with 1 range, 2 changeover contacts
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• Optionally energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Download datablad
Undercurrent Relay SL 9271CT
• According to IEC/EN 60 255, DIN VDE 0435-303
• IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: single phase
• Measuring ranges from 0.1 ... 100 A
• IK 9271, SK 9271:
with 4 ranges settable by rotational switch, 1 changeover contact
• IL 9271, SL 9271:
with 5 ranges settable by rotational switch, 1 changeover contact
with 4 ranges programmable by bridges, 2 changeover contacts
• IP 9271, SP 9271: with 1 range, 2 changeover contacts
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• Optionally energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Download datablad
Undercurrent Relay SP 9271CT
• According to IEC/EN 60 255, DIN VDE 0435-303
• IP 9271, SP 9271, SP 9271CT: 3-phase
IK 9271, IL 9271, SK 9271, SL 9271, SL 9271CT: single phase
• Measuring ranges from 0.1 ... 100 A
• IK 9271, SK 9271:
with 4 ranges settable by rotational switch, 1 changeover contact
• IL 9271, SL 9271:
with 5 ranges settable by rotational switch, 1 changeover contact
with 4 ranges programmable by bridges, 2 changeover contacts
• IP 9271, SP 9271: with 1 range, 2 changeover contacts
• Settable response value
• Fixed hysteresis
• Settable time delay
• De-energized on trip
• Optionally energized on trip
• LED indicators
• With auxiliary voltage
• Auxiliary supply and measuring input galvanic separated
• Devices available in 2 enclosure versions:
- I-model, e.g. IK _ _ _ _, depth 61 mm
with terminals at the bottom for installations systems
and industrial distribution systems according to DIN 43 880
- S-model, e.g. SK _ _ _ _, depth 100 mm
with terminals at the top for cabinets with mounting plate
and cable duct
• Width IK 9271, SK 9271: 17.5 mm
IL 9271, SL 9271, SL 9271CT: 35 mm
IP 9271, SP 9271, SP 9271CT: 70 mm
Download datablad
Undercurrent Relay IK 9273
• According to IEC/EN 60 255
• Single phase
• Measuring ranges from 0.05 ... 10 A
• Setting value adjustable from 0.1 ... 1 IN
• Fixed hysteresis approx. 4 %
• Settable switching delay
• Closed circuit operation
• Optionally open circuit operation
• Automatic reset
• Optionally manual reset, reset button on the front
• LED indication for auxiliary voltage and contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9273: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9273: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
Download datablad
Undercurrent Relay SK 9273
• According to IEC/EN 60 255
• Single phase
• Measuring ranges from 0.05 ... 10 A
• Setting value adjustable from 0.1 ... 1 IN
• Fixed hysteresis approx. 4 %
• Settable switching delay
• Closed circuit operation
• Optionally open circuit operation
• Automatic reset
• Optionally manual reset, reset button on the front
• LED indication for auxiliary voltage and contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 9273: depth 59 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 9273: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm
Download datablad
Current Monitor IK 8839
• According to IEC/EN 60 255, DIN VDE 0435-303
• Measuring range 0.175 ... 1 A
• Fixed switching point setting
• High maximum load
• As option with semiconductor output
• Width
IK 8839: 17.5 mm
IL 8839: 35 mm
Download datablad
Current Monitor IL 8839
• According to IEC/EN 60 255, DIN VDE 0435-303
• Measuring range 0.175 ... 1 A
• Fixed switching point setting
• High maximum load
• As option with semiconductor output
• Width
IK 8839: 17.5 mm
IL 8839: 35 mm
Download datablad
Current Monitor IK 9138
• According to IEC/EN 60 255, DIN VDE 0435-303
• Measuring range 0.175 ... 1 A
• Fixed switching point setting
• High maximum load
• As option with semiconductor output
• Width
IK 8839: 17.5 mm
IL 8839: 35 mm
Download datablad
Current Monitor IK 9139
• According to IEC/EN 60 255, DIN VDE 0435-303
• Measuring range 0.175 ... 1 A
• Fixed switching point setting
• High maximum load
• As option with semiconductor output
• Width
IK 8839: 17.5 mm
IL 8839: 35 mm
Download datablad
Current Relay RL 9853
• According to IEC/EN 60 255-1
• For monitoring of current in DC and AC systems
• Detection of over- or undercurrent in AC- or DC mains
• Wide auxiliary range
• Output: 1 changeover contact
• De-Energized on trip
• Adjustable switching current
• Adjustable hysteresis for reset
• Adjustable switching delay
• Fast fault detection
• Width: 35 mm
Download datablad