Softstartere

MINISTART - Intelligent, flexible and high-performance!

DOLD soft start devices of the MINISTART family ensure that your machines start up gently and smoothly and/or minimise a wide variety of problems such as mechanical wear during the direct start of drives, the tipping or sliding of loads on transport belts, pressure surges in the lines of pump systems and much more. They reduce the wear on and increase the service life of your motors and mechanical drive components. DOLD soft start devices offer additional advantages as a simple and space-saving installation, provide flexible configuration options and relieve the supplying grid through reduced starting current.
Softstarter with softstop UG 9019
• According to IEC/EN 60 947-4-2
• 2-phase softstart and softstop of 3-phase motors up to 4 KW
• 4 potentiometer für setting of starting torque, deceleration torque,
softstart /-stop
• 3 LEDs for status indication
• Reset button on front
• Connection facility for external reset button
• Relay indicator output for operation
• Galvanic separation between control circuit and power circuit
• Width 22,5 mm
Download datablad
Softstarter with soft coasting UH 9018
• Softstart with softstop
• For motors from 1.5 kW to 7.5 kW
• 2-phase control
• Adjustable ramp time, starting torque and starting voltage
• Kickstart-(Boost-)function
• DIN-rail mounting
• Width: 45 mm
Download datablad
Softstarter for heating pumps PF 9029
• According to IEC/EN 60 947-4-2
• 3-phase controlled with integrated bypass relays
• Phase sequence monitoring
• Undervoltage monitoring
• Overvoltage monitoring
• Blocked motor monitoring in bypass mode
• Integrated motor protection to class 10 acc. to IEC/EN 60947-4-2
• Starting current limitation
• Thyristor monitoring
• Detection of missing load
• Automatic frequency detection of supply voltage
• Temperature monitoring of power semiconductors
Download datablad
Softstarter IL 9017
• Increases life of 1-phase squirrel motors and mechanical drives
• Devices available in 2 enclosure version:
IL 9017: depth 61 mm with terminals at the bottom for
installations systems and industrial distribution systems
according to DIN 43 880
SL 9017: depth 100 mm with terminals at the top for
cabinets with mounting plate and cable duct
• For single phase motors up to 1.5 kW
• Adjustable ramp time and starting torque
• Semiconductors will be bridged after start up
• LED indication
• Width 35 mm
Download datablad
Softstarter SL 9017
• Increases life of 1-phase squirrel motors and mechanical drives
• Devices available in 2 enclosure version:
IL 9017: depth 61 mm with terminals at the bottom for
installations systems and industrial distribution systems
according to DIN 43 880
SL 9017: depth 100 mm with terminals at the top for
cabinets with mounting plate and cable duct
• For single phase motors up to 1.5 kW
• Adjustable ramp time and starting torque
• Semiconductors will be bridged after start up
• LED indication
• Width 35 mm
Download datablad
Softstarter with softstop IL 9017/300
• Increases life of 1-phase squirrel motors and mechanical drives
• For single phase motors up to 1.5 kW
• Adjustable ramp time/deceleration time and starting torque/
deceleration torque
• Semiconductors will be bridged after start up
• LED indication
• Width 35 mm
Download datablad
Softstarter BA 9010
• Increases the life of squirrel cage motors and mechanical drives
• Easily fitted to existing installations
• 1 phase control
• For motors up to 5,5 kW (BA 9010) and to 11 kW (BN 9011)
• Semiconductors bridged after softstart
• Adjustable ramp time and starting torque
• LED indication
• DIN-rail mounting
• BA 9010: width 45 mm
Download datablad
Softstarter BN 9011
• Increases the life of squirrel cage motors and mechanical drives
• Easily fitted to existing installations
• 1 phase control
• For motors up to 5,5 kW (BA 9010) and to 11 kW (BN 9011)
• Semiconductors bridged after softstart
• Adjustable ramp time and starting torque
• LED indication
• DIN-rail mounting
• BN 9011: width 100 mm
Download datablad
Softstarter BI 9028/900
• Softstart and softstop function
• According to IEC/EN 60 947-4-2
• 1-phase motor control
• For motors up to 5 kW at AC 230 V
• Separate settings for start and deceleration time, as well as
starting and deceleration torque
• Galvanic isolation of control input
with wide voltage range up to AC/DC 230 V
• 3 auxiliary voltages up to 230 V
• phase failure detection
• 2 relay outputs for indication of status and fault
• LED-indication
• 90 mm width
Download datablad
Softstart / Softstop with reverse function RP 9210/300
• According to EN 60 947-4-2
• For controlling of 3-phase motors up to 750 W
• With 2-phase softstart and softstop
• Temperature monitoring of the motors with PTC or thermal switch
• 3 potentiometer for adjustment of softstart, softstop
and starting - deceleration time
• 3 LED-indicators
• Reversing with relays, softstart and softstop with thyristors
• 2 x 24 V-inputs for clockwise rotation, anticlockwise rotation
• short circuit proof for 24 V monitoring output
• galvanic separation of control circuit and power circuit
• Width 72 mm
Download datablad
Softstart- / Softstop device GI 9014
• 2-phase softstarter for asynchronous motors up to 110 kW (400 V)
• Integrated current control time
• Integrated motor protector
• Integrated bridging contactor
• Volt free coltrol input for softstart / -stop
• Connection for motor thermistor
• With two monitoring outputs, one is programmable
• DIN rail mounting with devices up to 30 kW
• Communication interfaces for Profibus, DeviceNet,
Modbus and pump controls (optional)
• Start and stop via seperate push buttons or control switch
• Motor voltage range 3 AC 200 ... 440V or 3 AC 200 ... 575V

Adjustable functions:
• Starting time monitoring
• Nominal motor current
• Current ramp
• Current limit
• Softstopp - ramp time
• Motor protection class
• Phase sequence
• Programmable relay output for indicators
Download datablad
Softstarter and softstop device GF 9016
• For soft and shockfree start of your asynchronous motors
• Less wearing and longer life for your motors and components
• Space saving and easy fitting
• Reduce load from supply mains by reducing of starting current
• According to IEC/EN 60 947-4-2
• Softstart with softstop
• For motors up to 37 kW
• 2-phase control
• Adjustable start up and deceleration time als well as
starting voltage, optionally with kickstart
• Without auxiliary voltage
• W3 connection is possible
• As option current control on softstart
• Up to 15 kW: width 45 mm
Up to 22 kW: width 52.5 mm
Download datablad
Softstarter with softstop BA 9019
• Increases the life of squirrel cage motors and mechanical drives
• Easily fitted to existing installations
• 2-phase control softstart and softstop
• For motors up to 5.5 kW
• Start current limited to 2 to 3 times rated motor current
• Semiconductors bridged after softstart
• Adjustable ramp time, starting torque and deceleration time
• LED indication
• DIN rail mounting
• Galvanic isolation of control input and auxiliary power supply
• Integrated overtemperature monitoring
• Wide motor voltage range 200 to 460 V AC
• Width 45 mm
Download datablad
Softstarter BL 9025
• Softstart and softstop function
• 2-phase control
• For motors up to 15 kW at 3 AC 400 V
• Acceleration and deceleration time resp. starting and
switch-off torque are separately adjustable
• Wide input voltage range of the power semiconductors
• Galvanic isolation of control input with wide voltage range
up to AC/DC 480 V control input
• 3 auxiliary voltages at the device up to AC 230 V
• Integrated overtemperature monitoring
• LED indication
• According to EN 60 947-4-2
• 90 mm width
Download datablad
Softstarter BI 9025
• Softstart and softstop function
• 2-phase control
• For motors up to 15 kW at 3 AC 400 V
• Acceleration and deceleration time resp. starting and
switch-off torque are separately adjustable
• Wide input voltage range of the power semiconductors
• Galvanic isolation of control input with wide voltage range
up to AC/DC 480 V control input
• 3 auxiliary voltages at the device up to AC 230 V
• Integrated overtemperature monitoring
• LED indication
• According to EN 60 947-4-2
• 90 mm width
Download datablad
Softstarter with DC-brake BI 9028
• According to IEC/EN 60 947-4-2
• 2-phase motor control
• For motors up to 15 kW at 3 AC 400 V
• Separate settings for start and brake time, as well as starting
and braking torque
• Galvanic isolation of control input
with wide voltage range up to AC/DC 230 V
• No external motor or braking contactor necessary
• 3 auxiliary voltages up to 230 V
• monitors undervoltage and phase sequence
• 2 relay outputs for indication of status and fault
• LED-indication
• As option without auxiliary supply
• As option with voltfree contacts for start and stop
• As option with input to detect motor temperature
• BI 9028 up to 7.5 kW: 67.5 mm width
BI 9028 up to 15 kW: 90 mm width
Download datablad
Softstarter with DC-brake BL 9028Download datablad
Softstart- / Softstop device GI 9015
• 3-phase softstarter for asynchronous motors up to 800 kW (400 V)
• W3 connection up to 1300 kW (400V)
• Nominal current 23 ... 1600 A
• Integrated bridging contactor up to 220 A
• Programmable in- and outputs for fault indication and operation
• Motor-PTC connection possible
• Communication interfaces as option for Profibus, Devicenet or Modbus
• Start and stop via seperate push buttons or control switch

Adjustable functions:
• Emergency operation
• Slow motion operation forward and reverse
• Control input (3 x fixed, 1 x programmable)
• Relay output (3 x programmable)
• 24 V DC output
• Analogue output
• Different softstart / stop modes
• 690 V units on request
Download datablad
Softstarter with softstop BA 9026
• Increases the life of squirrel cage motors and mechanical drives
• Easily fitted to existing installations
• 3-phase control softstart and softstop
• For motors up to 5.5 kW
• Start current limited to 2 to 3 times rated motor current
• Semiconductors bridged after softstart
• Adjustable ramp time, starting torque and deceleration time
• LED indication
• DIN rail mounted
• Galvanic isolation of control input and auxiliary power supply
• Integrated overtemperature monitoring
• Wide motor voltage range 200 V AC
• Width 45 mm
Download datablad
Softstarter with softstop GE 9015
• Increases life of squirrel cage motors and mechanical drives
• Easily fitted to existing installations
• 3-phase control softstart and softstop
• For motors up to 55 kW
• Start current limited to 2 to 3 times rated motor current
• Semiconductors bridged after softstart
• Adjustable ramp time, starting torque and deceleration time
• Integrated temperature monitoring of semiconductors
• Thermistor temperature monitoring of the motor
• 7.5 ... 22 kW: enclosure width 304 mm
30 ... 55 kW: enclosure width 335 mm
Download datablad