The modular and configurable safety system SAFEMASTER PRO monitors all safety circuits of you machinery and installations – in a simple, flexible and safe way. The DOLD safety system consists of a control unit and up to 14 expansion modules. Pure input, pure output and combined input/output modules are available for the simple adjustment to the respective task. SAFEMASTER PRO is suitable for safety applications up to PL e / cat. 4 and SIL 3; its hardware and software are TÜV-certified. You can configure the system with SAFEMASTER PRO Designer. The projection takes place easily per drag & drop via the graphic configuration software.
![]() | Control unit UG 6911.10 • Monitoring of opto electronical sensors, light curtains, magnetic actuated sensors, E-stop buttons, safety mats, mechanical switches, two-hand control • 8 safety, single-channel inputs, dual-channel connection in pairs • 2 safety, dual-channel outputs (OSSD) • 4 separate test outputs for sensor monitoring • 1 Feedback circuit each für every safety output with individual configurable reset • Configuration by PC via Mini USB Port • Using as stand alone unit possible • Indicator output, status-LEDs and bus connection via field bus modules for comprehensive diagnostics • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Input / Output module UG 6916.10 • 8 safety, single-channel inputs, dual-channel connection in pairs • 2 seaprate safety, dual-channel outputs (OSSD) • 1 Feedback circuit each für every safety output with individual configurable reset • 4 separate test outputs for sensor monitoring • To extend Safemaster Pro via DIN rail bus (IN-Rail Bus) in an easy way • Status LEDs and 2 programmable status outputs for diagnosis • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Input module UG 6913.08 • 8, 12 or 16 safety, single-channel inputs, single-channel connection in pairs • 4 (UG 6913.08 and UG 6913.16) e.g. 8 (UG 6913.12) test outputs for sensor monitoring • To extend Safemaster Pro via DIN rail bus (IN-Rail Bus) in an easy way • Status LEDs for comprehensive diagnosis • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Input module UG 6913.12 • 8, 12 or 16 safety, single-channel inputs, single-channel connection in pairs • 4 (UG 6913.08 and UG 6913.16) e.g. 8 (UG 6913.12) test outputs for sensor monitoring • To extend Safemaster Pro via DIN rail bus (IN-Rail Bus) in an easy way • Status LEDs for comprehensive diagnosis • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Input module UG 6913.16 • 8, 12 or 16 safety, single-channel inputs, single-channel connection in pairs • 4 (UG 6913.08 and UG 6913.16) e.g. 8 (UG 6913.12) test outputs for sensor monitoring • To extend Safemaster Pro via DIN rail bus (IN-Rail Bus) in an easy way • Status LEDs for comprehensive diagnosis • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Output module OSSD UG 6912.02 • 2 or 4 safety dual channel semiconductor outputs (OSSD), separate control in pairs • To extend Safemaster Pro via DIN rail bus (IN-Rail Bus) in an easy way • One feedback circuit for each of the 2 or 4 safety outputs with individual start options • Status LEDs and 2 programmable status outputs for diagnosis • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Output module OSSD UG 6912.04 • 2 or 4 safety dual channel semiconductor outputs (OSSD), separate control in pairs • To extend Safemaster Pro via DIN rail bus (IN-Rail Bus) in an easy way • One feedback circuit for each of the 2 or 4 safety outputs with individual start options • Status LEDs and 2 programmable status outputs for diagnosis • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Output module Relay extension UG 6912.14 • Relay contact extension of the OSSDs of Safemaster Pro • UG 6912.14: 1 relay output with 2 NO safety contacts and 1 NC monitoring contact UG 6912.28: 2 relay output with 2 NO safety contacts each and 1 NC monitoring contact • Status LEDs for power and output • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Output module Relay extension UG 6912.28 • Relay contact extension of the OSSDs of Safemaster Pro • UG 6912.14: 1 relay output with 2 NO safety contacts and 1 NC monitoring contact UG 6912.28: 2 relay output with 2 NO safety contacts each and 1 NC monitoring contact • Status LEDs for power and output • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Output module Relay UG 6914.04/000 • 4 independent, single-channel safeta relay outputs configurable as: - 4 single outputs, safety category 1, with 1 NO contact - 4 single outputs, safety category 2, with 1 NO contact - 2 two-channel outputs, safety category 4, with 2 NO contacts • Optionally 8 freely usable, non-secure, solid-state reporting outputs (OUT-STATUS) • To extend SAFEMASTER PRO via DIN rail bus (IN-Rail Bus) in an easy way • 1 Feedback circuit each for 2 safety outputs with individual configurable reset • Status LEDs for comprehensive diagnosis • With pluggable terminal block for easy easy exchange of devises | Download Datablad |
![]() | Output module Relay UG 6914.04/008 • 4 independent, single-channel safeta relay outputs configurable as: - 4 single outputs, safety category 1, with 1 NO contact - 4 single outputs, safety category 2, with 1 NO contact - 2 two-channel outputs, safety category 4, with 2 NO contacts • Optionally 8 freely usable, non-secure, solid-state reporting outputs (OUT-STATUS) • To extend SAFEMASTER PRO via DIN rail bus (IN-Rail Bus) in an easy way • 1 Feedback circuit each for 2 safety outputs with individual configurable reset • Status LEDs for comprehensive diagnosis • With pluggable terminal block for easy easy exchange of devises | Download Datablad |
![]() | Speed monitoring module UG 6917/002 • Speed monitoring module for 1 to 2 axes • Terminal blocks for connecting 2 proximity sensors • Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos) • Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be configured. • Speed window monitoring • Standstill monitoring • For rotational or linear movements • For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS) • For safety applications up to PLe / cat. 4 or SIL 3 • Status LEDs for comprehensive diagnostics • Installation width: 22,5 mm | Download Datablad |
![]() | Speed monitoring module UG 6917/102 • Speed monitoring module for 1 to 2 axes • Terminal blocks for connecting 2 proximity sensors • Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos) • Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be configured. • Speed window monitoring • Standstill monitoring • For rotational or linear movements • For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS) • For safety applications up to PLe / cat. 4 or SIL 3 • Status LEDs for comprehensive diagnostics • Installation width: 22,5 mm | Download Datablad |
![]() | Speed monitoring module UG 6917/112 • Speed monitoring module for 1 to 2 axes • Terminal blocks for connecting 2 proximity sensors • Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos) • Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be configured. • Speed window monitoring • Standstill monitoring • For rotational or linear movements • For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS) • For safety applications up to PLe / cat. 4 or SIL 3 • Status LEDs for comprehensive diagnostics • Installation width: 22,5 mm | Download Datablad |
![]() | Speed monitoring module UG 6917/202 • Speed monitoring module for 1 to 2 axes • Terminal blocks for connecting 2 proximity sensors • Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos) • Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be configured. • Speed window monitoring • Standstill monitoring • For rotational or linear movements • For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS) • For safety applications up to PLe / cat. 4 or SIL 3 • Status LEDs for comprehensive diagnostics • Installation width: 22,5 mm | Download Datablad |
![]() | Speed monitoring module UG 6917/222 • Speed monitoring module for 1 to 2 axes • Terminal blocks for connecting 2 proximity sensors • Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos) • Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be configured. • Speed window monitoring • Standstill monitoring • For rotational or linear movements • For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS) • For safety applications up to PLe / cat. 4 or SIL 3 • Status LEDs for comprehensive diagnostics • Installation width: 22,5 mm | Download Datablad |
![]() | Speed monitoring module UG 6917/302 • Speed monitoring module for 1 to 2 axes • Terminal blocks for connecting 2 proximity sensors • Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos) • Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be configured. • Speed window monitoring • Standstill monitoring • For rotational or linear movements • For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS) • For safety applications up to PLe / cat. 4 or SIL 3 • Status LEDs for comprehensive diagnostics • Installation width: 22,5 mm | Download Datablad |
![]() | Speed monitoring module UG 6917/332 • Speed monitoring module for 1 to 2 axes • Terminal blocks for connecting 2 proximity sensors • Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos) • Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be configured. • Speed window monitoring • Standstill monitoring • For rotational or linear movements • For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS) • For safety applications up to PLe / cat. 4 or SIL 3 • Status LEDs for comprehensive diagnostics • Installation width: 22,5 mm | Download Datablad |
![]() | Bus Extender UG 6918 • Allows to devide the SAFEMASTER PRO System into serval remote groups • Allows safe, remote I/Os • Devides the system into 6 I/O groupes • Distance between groupes 50 m • Reduced wiring • With plugable terminal blocks for easy exchange of devices | Download Datablad |
![]() | Fieldbus module CANopen UG 6951 • Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB) • Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus) • Status LEDs for comprehensive diagnostic • No influence of the safety functions of SAFEMASTER PRO • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Fieldbus module PROFIBUS-DP UG 6952 • Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB) • Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus) • Status LEDs for comprehensive diagnostic • No influence of the safety functions of SAFEMASTER PRO • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Fieldbus module PROFINET UG 6954 • Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB) • Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus) • Status LEDs for comprehensive diagnostic • No influence of the safety functions of SAFEMASTER PRO • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Fieldbus module Ethernet/IP UG 6955 • Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB) • Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus) • Status LEDs for comprehensive diagnostic • No influence of the safety functions of SAFEMASTER PRO • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Fieldbus module EtherCAT UG 6956 • Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB) • Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus) • Status LEDs for comprehensive diagnostic • No influence of the safety functions of SAFEMASTER PRO • With pluggable terminal block for easy exchange of devices | Download Datablad |
![]() | Fieldbus module USB UG 6957 • Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB) • Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus) • Status LEDs for comprehensive diagnostic • No influence of the safety functions of SAFEMASTER PRO • With pluggable terminal block for easy exchange of devices | Download Datablad |