Konfigurerbart sikkerheds system

SAFEMASTER PRO - The configurable safety system - universal and expandable

The modular and configurable safety system SAFEMASTER PRO monitors all safety circuits of you machinery and installations – in a simple, flexible and safe way. The DOLD safety system consists of a control unit and up to 14 expansion modules. Pure input, pure output and combined input/output modules are available for the simple adjustment to the respective task. SAFEMASTER PRO is suitable for safety applications up to PL e / cat. 4 and SIL 3; its hardware and software are TÜV-certified. You can configure the system with SAFEMASTER PRO Designer. The projection takes place easily per drag & drop via the graphic configuration software.
Control unit UG 6911.10
• Monitoring of opto electronical sensors, light curtains, magnetic
actuated sensors, E-stop buttons, safety mats, mechanical switches,
two-hand control
• 8 safety, single-channel inputs, dual-channel connection in pairs
• 2 safety, dual-channel outputs (OSSD)
• 4 separate test outputs for sensor monitoring
• 1 Feedback circuit each für every safety output with individual
configurable reset
• Configuration by PC via Mini USB Port
• Using as stand alone unit possible
• Indicator output, status-LEDs and bus connection via field bus
modules for comprehensive diagnostics
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Input / Output module UG 6916.10
• 8 safety, single-channel inputs, dual-channel connection in pairs
• 2 seaprate safety, dual-channel outputs (OSSD)
• 1 Feedback circuit each für every safety output with individual
configurable reset
• 4 separate test outputs for sensor monitoring
• To extend Safemaster Pro via DIN rail bus (IN-Rail Bus)
in an easy way
• Status LEDs and 2 programmable status outputs for diagnosis
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Input module UG 6913.08
• 8, 12 or 16 safety, single-channel inputs, single-channel connection in pairs
• 4 (UG 6913.08 and UG 6913.16) e.g. 8 (UG 6913.12) test outputs
for sensor monitoring
• To extend Safemaster Pro via DIN rail bus (IN-Rail Bus)
in an easy way
• Status LEDs for comprehensive diagnosis
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Input module UG 6913.12
• 8, 12 or 16 safety, single-channel inputs, single-channel connection in pairs
• 4 (UG 6913.08 and UG 6913.16) e.g. 8 (UG 6913.12) test outputs
for sensor monitoring
• To extend Safemaster Pro via DIN rail bus (IN-Rail Bus)
in an easy way
• Status LEDs for comprehensive diagnosis
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Input module UG 6913.16
• 8, 12 or 16 safety, single-channel inputs, single-channel connection in pairs
• 4 (UG 6913.08 and UG 6913.16) e.g. 8 (UG 6913.12) test outputs
for sensor monitoring
• To extend Safemaster Pro via DIN rail bus (IN-Rail Bus)
in an easy way
• Status LEDs for comprehensive diagnosis
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Output module OSSD UG 6912.02
• 2 or 4 safety dual channel semiconductor outputs (OSSD),
separate control in pairs
• To extend Safemaster Pro via DIN rail bus (IN-Rail Bus)
in an easy way
• One feedback circuit for each of the 2 or 4 safety outputs with individual
start options
• Status LEDs and 2 programmable status outputs for diagnosis
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Output module OSSD UG 6912.04
• 2 or 4 safety dual channel semiconductor outputs (OSSD),
separate control in pairs
• To extend Safemaster Pro via DIN rail bus (IN-Rail Bus)
in an easy way
• One feedback circuit for each of the 2 or 4 safety outputs with individual
start options
• Status LEDs and 2 programmable status outputs for diagnosis
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Output module Relay extension UG 6912.14
• Relay contact extension of the OSSDs of Safemaster Pro
• UG 6912.14: 1 relay output with 2 NO safety contacts and
1 NC monitoring contact
UG 6912.28: 2 relay output with 2 NO safety contacts each and
1 NC monitoring contact
• Status LEDs for power and output
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Output module Relay extension UG 6912.28
• Relay contact extension of the OSSDs of Safemaster Pro
• UG 6912.14: 1 relay output with 2 NO safety contacts and
1 NC monitoring contact
UG 6912.28: 2 relay output with 2 NO safety contacts each and
1 NC monitoring contact
• Status LEDs for power and output
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Output module Relay UG 6914.04/000
• 4 independent, single-channel safeta relay outputs configurable as:
- 4 single outputs, safety category 1, with 1 NO contact
- 4 single outputs, safety category 2, with 1 NO contact
- 2 two-channel outputs, safety category 4, with 2 NO contacts
• Optionally 8 freely usable, non-secure, solid-state reporting outputs (OUT-STATUS)
• To extend SAFEMASTER PRO via DIN rail bus (IN-Rail Bus) in an easy way
• 1 Feedback circuit each for 2 safety outputs with individual configurable reset
• Status LEDs for comprehensive diagnosis
• With pluggable terminal block for easy easy exchange of devises
Download
Datablad
Output module Relay UG 6914.04/008
• 4 independent, single-channel safeta relay outputs configurable as:
- 4 single outputs, safety category 1, with 1 NO contact
- 4 single outputs, safety category 2, with 1 NO contact
- 2 two-channel outputs, safety category 4, with 2 NO contacts
• Optionally 8 freely usable, non-secure, solid-state reporting outputs (OUT-STATUS)
• To extend SAFEMASTER PRO via DIN rail bus (IN-Rail Bus) in an easy way
• 1 Feedback circuit each for 2 safety outputs with individual configurable reset
• Status LEDs for comprehensive diagnosis
• With pluggable terminal block for easy easy exchange of devises
Download
Datablad
Speed monitoring module UG 6917/002
• Speed monitoring module for 1 to 2 axes
• Terminal blocks for connecting 2 proximity sensors
• Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos)
• Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be
configured.
• Speed window monitoring
• Standstill monitoring
• For rotational or linear movements
• For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS)
• For safety applications up to PLe / cat. 4 or SIL 3
• Status LEDs for comprehensive diagnostics
• Installation width: 22,5 mm
Download
Datablad
Speed monitoring module UG 6917/102
• Speed monitoring module for 1 to 2 axes
• Terminal blocks for connecting 2 proximity sensors
• Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos)
• Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be
configured.
• Speed window monitoring
• Standstill monitoring
• For rotational or linear movements
• For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS)
• For safety applications up to PLe / cat. 4 or SIL 3
• Status LEDs for comprehensive diagnostics
• Installation width: 22,5 mm
Download
Datablad
Speed monitoring module UG 6917/112
• Speed monitoring module for 1 to 2 axes
• Terminal blocks for connecting 2 proximity sensors
• Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos)
• Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be
configured.
• Speed window monitoring
• Standstill monitoring
• For rotational or linear movements
• For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS)
• For safety applications up to PLe / cat. 4 or SIL 3
• Status LEDs for comprehensive diagnostics
• Installation width: 22,5 mm
Download
Datablad
Speed monitoring module UG 6917/202
• Speed monitoring module for 1 to 2 axes
• Terminal blocks for connecting 2 proximity sensors
• Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos)
• Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be
configured.
• Speed window monitoring
• Standstill monitoring
• For rotational or linear movements
• For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS)
• For safety applications up to PLe / cat. 4 or SIL 3
• Status LEDs for comprehensive diagnostics
• Installation width: 22,5 mm
Download
Datablad
Speed monitoring module UG 6917/222
• Speed monitoring module for 1 to 2 axes
• Terminal blocks for connecting 2 proximity sensors
• Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos)
• Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be
configured.
• Speed window monitoring
• Standstill monitoring
• For rotational or linear movements
• For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS)
• For safety applications up to PLe / cat. 4 or SIL 3
• Status LEDs for comprehensive diagnostics
• Installation width: 22,5 mm
Download
Datablad
Speed monitoring module UG 6917/302
• Speed monitoring module for 1 to 2 axes
• Terminal blocks for connecting 2 proximity sensors
• Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos)
• Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be
configured.
• Speed window monitoring
• Standstill monitoring
• For rotational or linear movements
• For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS)
• For safety applications up to PLe / cat. 4 or SIL 3
• Status LEDs for comprehensive diagnostics
• Installation width: 22,5 mm
Download
Datablad
Speed monitoring module UG 6917/332
• Speed monitoring module for 1 to 2 axes
• Terminal blocks for connecting 2 proximity sensors
• Available with 0,1 or 2RJ45 sockets for connecting encoders (TTl, HTL, sin/cos)
• Speed pre-selection, with or without direction monitoring. Up to 4 speed thresholds can be
configured.
• Speed window monitoring
• Standstill monitoring
• For rotational or linear movements
• For simple expansion of SAFEMASTER PRO via DIN rai lbus (IN-RAIL-BUS)
• For safety applications up to PLe / cat. 4 or SIL 3
• Status LEDs for comprehensive diagnostics
• Installation width: 22,5 mm
Download
Datablad
Bus Extender UG 6918
• Allows to devide the SAFEMASTER PRO System into serval remote
groups
• Allows safe, remote I/Os
• Devides the system into 6 I/O groupes
• Distance between groupes 50 m
• Reduced wiring
• With plugable terminal blocks for easy exchange of devices
Download
Datablad
Fieldbus module CANopen UG 6951
• Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB)
• Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus)
• Status LEDs for comprehensive diagnostic
• No influence of the safety functions of SAFEMASTER PRO
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Fieldbus module PROFIBUS-DP UG 6952
• Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB)
• Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus)
• Status LEDs for comprehensive diagnostic
• No influence of the safety functions of SAFEMASTER PRO
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Fieldbus module PROFINET UG 6954
• Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB)
• Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus)
• Status LEDs for comprehensive diagnostic
• No influence of the safety functions of SAFEMASTER PRO
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Fieldbus module Ethernet/IP UG 6955
• Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB)
• Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus)
• Status LEDs for comprehensive diagnostic
• No influence of the safety functions of SAFEMASTER PRO
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Fieldbus module EtherCAT UG 6956
• Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB)
• Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus)
• Status LEDs for comprehensive diagnostic
• No influence of the safety functions of SAFEMASTER PRO
• With pluggable terminal block for easy exchange of devices
Download
Datablad
Fieldbus module USB UG 6957
• Field bus modules for diagnostic-connetcion on field bus systems UG 6951 (CANopen), UG 6952 (Profibus DP), UG 6954 (PROFINET), UG 6955 (Ethernet/IP), UG 6956 (EtherCAT), UG 6957 (USB)
• Easy connection on SAFEMASTER PRO system via rail (IN-Rail Bus)
• Status LEDs for comprehensive diagnostic
• No influence of the safety functions of SAFEMASTER PRO
• With pluggable terminal block for easy exchange of devices
Download
Datablad