Specielle enheder

Special devices from DOLD include emergency stop monitors for the fast localisation of actuated emergency stop buttons, emergency stop devices and magnetically coded safety switches. The DOLD emergency stop monitors help to quickly and easily located actuated emergency stop buttons. This can significantly reduce the standstill times of machines and systems. Emergency stop devices from DOLD deactivate machines and/or place them in standstill. This thus reduces dangers to persons or damage to machinery as well as the manufactured products. With the coded magnetic switches from DOLD, the position of movable, rotatable or removable safety doors is monitored. The contactless devices can also be used for doors that are difficult to move or that are imprecisely positioned.
Emergency stop monitor BH 5922
• To monitor max. 16 single-channel e-stop buttons
or 8 2-channel e-stop buttons
• E-stop button can be connected directly to BH 5922
• Simple wiring of e-stop buttons
• Extendable in steps of 8 e.g. 16 inputs
• No influence on e-stop system
• Adjustable
- with manual reset (without link X1 / X2)
- with automatic reset (with link X1 / X2)
• Reset button and remote reset
• LED indicators to show the state of the e-stop buttons
• As option direct connection of 2-channel e-stop buttons to
BH 5922 / BL 5922
• As option with BCD output (high or low active) or CANopen
• As option with CANopen according to DS301 version 3.0
• as option with Profibus DP-V0
• BH 5922: width 45 mm
BL 5922: width 90 mm
Download datablad
Emergency stop monitor BL 5922
• To monitor max. 16 single-channel e-stop buttons
or 8 2-channel e-stop buttons
• E-stop button can be connected directly to BH 5922
• Simple wiring of e-stop buttons
• Extendable in steps of 8 e.g. 16 inputs
• No influence on e-stop system
• Adjustable
- with manual reset (without link X1 / X2)
- with automatic reset (with link X1 / X2)
• Reset button and remote reset
• LED indicators to show the state of the e-stop buttons
• As option direct connection of 2-channel e-stop buttons to
BH 5922 / BL 5922
• As option with BCD output (high or low active) or CANopen
• As option with CANopen according to DS301 version 3.0
• as option with Profibus DP-V0
• BH 5922: width 45 mm
BL 5922: width 90 mm
Download datablad
Valve monitoring module BH 5904
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Category 4 to EN 954-1
• Way of valve monitoring adjustable (2 NC, 2NO, 1 changeover
contact)
• Reset button to acknowledge after fault detection
• Available with continuous monitoring of the valve or just with one
check per cycle
• Contact reinforcement by external contactors possible
• Short circuit and cross fault detection
• Broken wire detection
• Outputs: 2 NO contacts
• 2 semiconductor outputs with short circuit, overload and
temperature protection to monitor the status
• Under and overvoltage detection
• Reaction time: max. 28 ms
• LED operation indicators (run 1, run 2 )
• Width 45 mm
Download datablad
Emergency stop device NI 5061
• NI 5061.06: Emergency stop with 2 NC contacts (forced opening)
NI 5061.43: Emergency stop with 2 NC contacts (forced opening) +
1 NO contact
• M12-connection
NI 5061.06: 4-poles
NI 5061.43: 8-poles
• Twist release left or right
• Foolproof acc. to EN ISO 13850
• A ccording to EN 60947-5-1, EN 60947-5-5
Download datablad
Safety switch magnetic coded NE 5020
• Usable for safety application by using a correctly installed and
connected, security module (e. g. BG 5925/920 or LG 5925/920)
• According to IEC/EN 60 204-1, EN 1088
• 2 channel system
• Standard switching distance: San ≤ 5.5 mm
Sab ≥ 13 mm
• 2 NO semiconductor outputs providing diversity and redundancy
• Magnetic coded, safe against manipulation
• Open end connection wires
• M8 or M12 connector as option
• Long service life
• Easy to mount
• Resistant against vibration
• Not sensitive to external magnetic fields
• Protection class IP 67
• LED indicator
Download datablad
Safety switch magnetic coded NE 5021
• Usable for safety application by using a correctly installed and
connected, security module (e. g. BG 5925/920 or LG 5925/920)
• According to IEC/EN 60 204-1
• Standard switching distance: San ≤ 7 mm
Sab ≥ 18 mm
• Max. number of switches in series:
- 6 NE 5021 on control unit BG 5925/920 or LG 5925/920
- 10 NE 5021 on multifunctional safety timer UG 6960 and UG 6961
- 10 NE 5021 on multifunctional safety module UG 6980
- 20 NE 5021 on multifunctional safety module UG 6970
- 20 NE 5021 on multifunction module BH 5910
• 2 NO contacts or 2 NO contacts / 1 NC contact
• Contacts protected against welding
• Very long service life
• Easy to mount and service
• Manipulation is difficult due to coded sensor
• Protection class IP 67
Download datablad