![]() | Speed or stand-still monitor BH 5932 • According to - Performance Level (PL) e and category 3 to EN ISO 13849-1: 2008 - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061 - Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 • For stop category 0 according to EN 418 • 2-channel input • To monitor rotation and linear movement • PNP proximity sensor inputs • Optionally inputs for NPN proximity sensors • Monitoring of connected sensor • Fixed setting, adjustable as option • Energized when speed is under setting value • LED indication • Feedback circuit X1 - X2 to monitor external contacts • Forcibly guided contacts • 2 NO, 1 NC contact • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3 • Width 45 mm | Download datablad |
![]() | Speed monitor UH 6932 • According to - Performance Level (PL) e und category 4 to EN ISO 13849-1: 2008 - SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061 - Safety Integrity Level (SIL 3) to IEC/EN 61508 - Safety Integrity Level (SIL) 3 to IEC/EN 61511 • Overspeed, underspeed or window monitoring • Integrated user friendly frontside display - Comfortable, menu guided configuration - For set point and actual value of Hz • Fast reaction time by measuring duration of cycle of input frequency • For PNP- or NPN-sensors • Adjustable hysteresis • Adjustable reset delay function from 0 ... 100 s • Adjustable start up time delay from 0 ... 100 s • Adjustable alarm delay from 0.1 ... 100 s • Manual or auto-reset • 2-channel function • Forcibly guided output contacts • LED-indicators and 2 semiconductor monitoring output • Width 45 mm • With pluggable terminal blocks for easy exchange of devices • Variant /_ _1: - it is possible to set a variety of response parameters by means of a 4 bit selection facility from an overriding control unit; - analog output (2 V to 10 V) corresponding to the current speed; - the possibility of overriding the speed by a supervisory function (muting); - adjustable switchover time from 0 ... 100 s | Download datablad |
![]() | Speed and frequency monitor UH 6937 • According to - Performance Level (PL) e und category 4 to EN ISO 13849-1 - SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061 - Safety Integrity Level (SIL 3) to IEC/EN 61508 - Safety Integrity Level (SIL) 3 to IEC/EN 61511 • Over-, underfrequency or window monitoring of single or 3-phase in AC systems • Integrated user friendly frontside display - Comfortable, menu guided configuration - For set point and actual value of Hz • Fast reaction time by measuring duration of cycle of input frequency • Universal measuring inputs for AC-voltages of 8 ... 280 V for single-phase monitoring as well as 16 ... 690 V for single- and 3-phase monitoring • Suitable for inverters - Variant /0_ _ : 1 ... 700 Hz - Variant /1_ _ : 1 ... 1200 Hz • Adjustable hysteresis • Adjustable reset delay function from 0 ... 100 s • Adjustable start up time delay from 0 ... 100 s • Adjustable alarm delay from 0.1 ... 100 s • Manual or auto-reset • galvanic separation between measuring input, auxiliary voltage and output contacts • 2-channel function • Forcibly guided output contacts • LED-indicators and 2 semiconductor monitoring output • Width 45 mm • With pluggable terminal blocks for easy exchange of devices • Variant /_ _1: - it is possible to set a variety of response parameters by means of a 4 bit selection facility from an overriding control unit; - analog output (2V to 10V) corresponding to the current speed; - the possibility of overriding the speed by a supervisory function (muting); - adjustable switchover time from 0 ... 100 s | Download datablad |
![]() | Speed monitor UH 5947 • According to - Performance Level (PL) e und category 4 to EN ISO 13849-1: 2008 - SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061 - Safety Integrity Level (SIL 3) to IEC/EN 61508 • According to EN 60204 • Device setting on menu-driven display or via RJ45 (FCC Western-Modular 8P8C) with connection cable (copy function) • Change tracking • Adjustable operation mode - Automatic mode: Monitoring of automatic rotational speed window and standstill speed. - Setup mode: Monitoring of setup rotational speed window. Standstill is permanently enabled. • Single or 2-channel safety gate monitoring • Integrated user friendly display for parameters and operation status - for set point and actual value of U/min or m/min - set point display also as frequency value - with numerous diagnostic features • Adjustable start up delay (0 ... 999 s) • Adjustable time delay for standstill detection (13/14, 23/24) (0 ... 999 s) • Adjustable monitoring time for feedback circuit RF1 (0,5 ... 999 s) • Monitoring of an release magnet • Monitoring of feedback circuits • Activation of the output path 43/44, 53/54 with on/off pushbutton with short circuit detection or automatic making function • Adjustable PNP- or NPN-sensors • Connection of different encodern possible (sin/cos, TTL, HTL) • 2-channel function • Forcibly guided contacts • LED-indicators and 2 semiconductor monitoring output • With pluggable terminal blocks for easy exchange of devices - with screw terminals - or with cage clamp terminals • Width 45 mm | Download datablad |
![]() | Stand-still monitor LH 5946 • According to - Performance Level (PL) e and category 4 to EN ISO 13849-1 - SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061 - Safety Integrity Level (SIL) 3 to IEC/EN 61508, IEC/EN 61511 and EN 61800-5-2 • Safe standstill detection on 3- and single-phase motors • No external sensors necessary • Independent of direction • Broken wire detection • Forcibly guided safety contacts: 3 NO contacts, 1 NC contact for AC 250 V • 2 semiconductor monitoring outputs • 1 monitoring output (NO contact) • Adjustable voltage setting • Adjustable standstill time delay • LED indicators for standstill, event of line breakage and operation voltage • Suitable for operation with inverters • Width 45 mm | Download datablad |
Du er her: Hjem > Producenter > DOLD > Relæ Moduler > Sikkerheds Teknologi > Stilstand & hastighedsovervågning
Stilstand & hastighedsovervågning
In accordance with the new machinery directive, the operating condition of a drive must be safely monitored and maintained during its shut-down. Typical applications are the release of locking mechanisms after the standstill of dangerous movements has been detected as well as work with open safety devices and reduced speed during calibration of the machine. The new speed monitors of the SAFEMASTER S series detect and signal the standstill and overspeed of machines and systems in automatic as well as set up operation. Its safely integrated safety door monitoring additionally provides a higher productivity and a higher degree of safety for the operating personnel.
Rådgivning
Vi står altid klar til at hjælpe dig og rådgive dig om hvilket produkt du skal have
Prismatch
Vi har prismatch på alle vores produkter. Se mere her
Indhent pris
Se prisen på dit produkt