The CANopen input and output modules (CANopen I/O modules) from DOLD are peripheral components of the CANopen SPS. With DOLD, you get the central components of the control system for machines and systems from a single source. Both analogue and digital bus modules are available for the field bus system CANopen. Thanks to their compact size, they are simply to install in a space-saving manner in installation distributors. Potential-free relay outputs ensure an interference-free operation.
![]() | Input module, digital IP 5502 • According to IEC/EN 61 131-2, IEC/EN 50 178 • CANopen interface according to DS301 version 3.0 (Plug and Play selectable), as option with galvanic separation • 8 digital inputs for DC 24 V • LED indicators for supply voltage and Bus status • 70 mm width | Download datablad |
![]() | Input module, analog IL 5508 • According to IEC/EN 61 131-2 • CANopen interface according to DS301 version 3.0, DS401 • 2 analogue inputs with each 2 x 0 ... 10 V, 2 x 0 ... 20 mA or 2 x Pt 100 (- 50 ... 300°C) • Galvanic separation between inputs, bus and auxiliary supply • LED indicators for supply voltage and Bus status • 35 mm width | Download datablad |
![]() | Output module, digital IP 5503 • According to IEC/EN 61 131-2, IEC/EN 50 178 • CANopen interface according to DS301 version 3.0 (Plug and Play selectable), as option with galvanic separation • 8 relay outputs • LED indicators for supply voltage, Bus status and state of contact • 70 mm width | Download datablad |
![]() | Output module, analog IL 5507 • For installation in consumer units or industrial cabinets • Space saving with 2 analogue outputs at 35 mm width required space not more then for 2 standard line circuit breakers • 2 analogue outputs, optionally with each 2 x 0 ... 10 V, 2 x 0 ... 20 mA, 2 x -10 V ... +10V oder 2 x 4 ... 20 mA • 12 bit resolution allows accuracy of < ± 0.1 % • Galvanic separation between logic, output and bus guarantees high interference immunity • No external voltage source necessary for output signal • Can be used in all CANopen networks due to high data transmission rate up to 1Mbit/s • Free configuration software CoDeSys • According to IEC/EN 61 131-2 • CANopen interface according to DS301 version 3.0, DS401 • LED indicators for supply voltage and Bus status | Download datablad |
![]() | I/O module, digital IN 5509 • According to IEC/EN 61 131-2 • CANopen interface according to DS 301 version 3.0, DS 401 • 4 digital inputs for DC 24 V • 4 relay outputs • LED indicators • 52.5 mm width | Download datablad |